{"id":300,"date":"2017-09-04T11:49:07","date_gmt":"2017-09-04T14:49:07","guid":{"rendered":"https:\/\/togawaengenharia.com.br\/blog\/?p=300"},"modified":"2026-04-06T08:06:49","modified_gmt":"2026-04-06T11:06:49","slug":"alimentacao-de-agua-da-caldeira","status":"publish","type":"post","link":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/","title":{"rendered":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira"},"content":{"rendered":"<p align=\"justify\">A alimenta\u00e7\u00e3o de \u00e1gua na caldeira \u00e9 a reposi\u00e7\u00e3o da \u00e1gua que \u00e9 transformada em vapor pela caldeira. Caso n\u00e3o haja reposi\u00e7\u00e3o, a quantidade de \u00e1gua dentro da caldeira diminui e os tubos superaquecem, causando danos na estrutura e poss\u00edveis acidentes.<\/p>\n<p align=\"justify\">Um sistema de alimenta\u00e7\u00e3o de \u00e1gua da caldeira \u00e9 composto basicamente por:<\/p>\n<ul>\n<li>tanque de alimenta\u00e7\u00e3o<\/li>\n<li>bomba de \u00e1gua<\/li>\n<li>\u00e1gua de reposi\u00e7\u00e3o (make up)<\/li>\n<li>tratamento da \u00e1gua de reposi\u00e7\u00e3o (abrandamento, osmose)<\/li>\n<li>retorno de condensado<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-301\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg\" alt=\"\" width=\"300\" height=\"207\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-768x530.jpg 768w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-750x518.jpg 750w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-400x276.jpg 400w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-430x297.jpg 430w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-150x104.jpg 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-100x69.jpg 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg 892w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Exemplo de sistema de alimenta\u00e7\u00e3o de \u00e1gua de caldeira<\/i><\/p>\n<p align=\"justify\">A alimenta\u00e7\u00e3o da \u00e1gua na caldeira se d\u00e1, tipicamente, por bombas centr\u00edfugas de alta press\u00e3o (normalmente multiest\u00e1gio) acionada por motor el\u00e9trico. Para caldeiras de combust\u00edvel s\u00f3lido, \u00e9 necess\u00e1ria a adi\u00e7\u00e3o de uma injetora: sistema de alimenta\u00e7\u00e3o similar a uma bomba de deslocamento positivo acionado por vapor produzido pela pr\u00f3pria caldeira.<\/p>\n<p align=\"justify\">\u00c9 recomendado que essa bomba de alimenta\u00e7\u00e3o possua faixa de opera\u00e7\u00e3o na qual a press\u00e3o seja pelo menos 30% superior a press\u00e3o de opera\u00e7\u00e3o da caldeira e a vaz\u00e3o m\u00ednima seja pelo menos igual a sua produ\u00e7\u00e3o m\u00e1xima.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-302\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-300x276.jpg\" alt=\"\" width=\"300\" height=\"276\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-300x276.jpg 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-400x368.jpg 400w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-430x396.jpg 430w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-150x138.jpg 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2-100x92.jpg 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.2.jpg 652w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Exemplo de curva de sele\u00e7\u00e3o de bomba<\/i><\/p>\n<p align=\"justify\">Tipicamente, a entrada da \u00e1gua de alimenta\u00e7\u00e3o na caldeira pode ser por dois locais: pelo fundo da caldeira, pr\u00f3ximo ao dep\u00f3sito da lama ou no meio, ou por cima, na regi\u00e3o do vapor. O crit\u00e9rio de decis\u00e3o est\u00e1 na temperatura da \u00e1gua de alimenta\u00e7\u00e3o e do projeto da caldeira. Quando a \u00e1gua de alimenta\u00e7\u00e3o \u00e9 \u201cfria\u201d (&lt;60\u00b0C), \u00e9 recomendado que a inje\u00e7\u00e3o de \u00e1gua se d\u00ea pela regi\u00e3o da lama. Se a \u00e1gua for \u201cquente\u201d, pode-se alimentar pela parte de vapor. Isso porque a inje\u00e7\u00e3o de \u00e1gua fria na regi\u00e3o de vapor causa choque t\u00e9rmico que pode danificar o vaso e varia\u00e7\u00e3o na press\u00e3o de trabalho.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-303\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-300x228.png\" alt=\"\" width=\"300\" height=\"228\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-300x228.png 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-400x303.png 400w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-430x326.png 430w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-150x114.png 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3-100x76.png 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.3.png 480w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Esquema de controle de n\u00edvel e acionamento da bomba on\/off.<\/i><\/p>\n<p align=\"justify\">Outra forma de minimizar o problema do choque t\u00e9rmico \u00e9 manter a alimenta\u00e7\u00e3o da \u00e1gua constante, ou seja, variar a vaz\u00e3o da bomba de alimenta\u00e7\u00e3o em fun\u00e7\u00e3o da produ\u00e7\u00e3o de vapor ou do n\u00edvel de \u00e1gua dentro da caldeira com sa\u00edda de sinal proporcional.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-304\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-300x180.png\" alt=\"\" width=\"300\" height=\"180\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-300x180.png 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-400x241.png 400w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-430x259.png 430w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-150x90.png 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4-100x60.png 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.4.png 542w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Sistema de controle modulado<\/i><\/p>\n<p align=\"justify\">Sempre que poss\u00edvel, a varia\u00e7\u00e3o da vaz\u00e3o deve ser feita por sistema de controle variado do motor da bomba, como inversores de frequ\u00eancia, por exemplo. Caso n\u00e3o seja poss\u00edvel, pode-se controlar a vaz\u00e3o da bomba com a utiliza\u00e7\u00e3o de uma v\u00e1lvula moduladora, que abre ou fecha conforme sinal de entrada. Nesse \u00faltimo caso, \u00e9 recomendada a instala\u00e7\u00e3o de um sistema de recircula\u00e7\u00e3o para garantir a vaz\u00e3o m\u00ednima e evitar o superaquecimento da bomba.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-306\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.5-300x173.png\" alt=\"\" width=\"300\" height=\"173\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.5-300x173.png 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.5-150x87.png 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.5-100x58.png 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.5.png 388w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Sistema de recircula\u00e7\u00e3o<\/i><\/p>\n<p align=\"justify\">Vale ressaltar que o tipo de sistema de alimenta\u00e7\u00e3o, a especifica\u00e7\u00e3o das bombas e o grau de automa\u00e7\u00e3o dependem muito de cada caldeira e do consumo energ\u00e9tico demandado pelo sistema.<\/p>\n<p align=\"justify\">Para instala\u00e7\u00e3o da bomba de alimenta\u00e7\u00e3o \u00e9 necess\u00e1rio confirmar o NPSHr da mesma e o NPSHa do sistema para evitar problemas com cavita\u00e7\u00e3o. Al\u00e9m disso, \u00e9 recomendado instalar a bomba entre v\u00e1lvulas de bloqueio, filtro Y e man\u00f4metro.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-medium wp-image-307\" src=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-300x128.jpg\" alt=\"\" width=\"300\" height=\"128\" srcset=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-300x128.jpg 300w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-768x329.jpg 768w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-750x321.jpg 750w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-400x171.jpg 400w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-430x184.jpg 430w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-150x64.jpg 150w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6-100x43.jpg 100w, https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.6.jpg 804w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p align=\"center\"><i>Exemplo de instala\u00e7\u00e3o da bomba<\/i><\/p>\n<p align=\"justify\">Quanto ao tanque de alimenta\u00e7\u00e3o, \u00e9 recomendado que este tenha volume equivalente a uma hora de produ\u00e7\u00e3o da caldeira e seja instalado em local elevado, principalmente se a \u00e1gua de alimenta\u00e7\u00e3o for superior a 80\u00b0C, para evitar problemas de cavita\u00e7\u00e3o na bombas. A altura recomendada depende de cada bomba e do seu ponto de opera\u00e7\u00e3o.<\/p>\n<p align=\"justify\">Essa \u00e9 uma vis\u00e3o geral do sistema de alimenta\u00e7\u00e3o de caldeiras. Mas qualquer d\u00favida mais espec\u00edfica ou coment\u00e1rios, entre em contato: <b>contato@togawaengenharia.com.br<\/b>, estamos sempre interessados em conhecer e aprender mais.<\/p>\n<p align=\"justify\">Refer\u00eancia:<\/p>\n<ul>\n<li><a href=\"http:\/\/www.spiraxsarco.com\/resources\/pages\/steam-engineering-tutorials.aspx\">Spirax Sarco<\/a><\/li>\n<li>Imagens: Spirax Sarco, Miura e Internet.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>A alimenta\u00e7\u00e3o de \u00e1gua na caldeira \u00e9 a reposi\u00e7\u00e3o da \u00e1gua que \u00e9 transformada em vapor pela caldeira. Caso n\u00e3o [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[9],"tags":[20,19],"class_list":["post-300","post","type-post","status-publish","format-standard","hentry","category-industria","tag-caldeira","tag-vapor"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia\" \/>\n<meta property=\"og:url\" content=\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\" \/>\n<meta property=\"og:site_name\" content=\"Togawa Engenharia\" \/>\n<meta property=\"article:published_time\" content=\"2017-09-04T14:49:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-06T11:06:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"892\" \/>\n\t<meta property=\"og:image:height\" content=\"616\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Victor Togawa\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Victor Togawa\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\"},\"author\":{\"name\":\"Victor Togawa\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/person\/2b97ffcae08c230f737a2572c9cb161d\"},\"headline\":\"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira\",\"datePublished\":\"2017-09-04T14:49:07+00:00\",\"dateModified\":\"2026-04-06T11:06:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\"},\"wordCount\":674,\"publisher\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#organization\"},\"image\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg\",\"keywords\":[\"caldeira\",\"vapor\"],\"articleSection\":[\"Ind\u00fastria\"],\"inLanguage\":\"pt-BR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\",\"url\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\",\"name\":\"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia\",\"isPartOf\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg\",\"datePublished\":\"2017-09-04T14:49:07+00:00\",\"dateModified\":\"2026-04-06T11:06:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage\",\"url\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg\",\"contentUrl\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg\",\"width\":892,\"height\":616},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/togawaengenharia.com.br\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#website\",\"url\":\"https:\/\/togawaengenharia.com.br\/blog\/\",\"name\":\"Togawa Engenharia\",\"description\":\"Blog Industrial\",\"publisher\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/togawaengenharia.com.br\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#organization\",\"name\":\"Togawa Engenharia\",\"url\":\"https:\/\/togawaengenharia.com.br\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2016\/08\/Logo-togawa1.png\",\"contentUrl\":\"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2016\/08\/Logo-togawa1.png\",\"width\":227,\"height\":71,\"caption\":\"Togawa Engenharia\"},\"image\":{\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/person\/2b97ffcae08c230f737a2572c9cb161d\",\"name\":\"Victor Togawa\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g\",\"caption\":\"Victor Togawa\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/","og_locale":"pt_BR","og_type":"article","og_title":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia","og_url":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/","og_site_name":"Togawa Engenharia","article_published_time":"2017-09-04T14:49:07+00:00","article_modified_time":"2026-04-06T11:06:49+00:00","og_image":[{"width":892,"height":616,"url":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg","type":"image\/jpeg"}],"author":"Victor Togawa","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Victor Togawa","Est. tempo de leitura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#article","isPartOf":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/"},"author":{"name":"Victor Togawa","@id":"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/person\/2b97ffcae08c230f737a2572c9cb161d"},"headline":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira","datePublished":"2017-09-04T14:49:07+00:00","dateModified":"2026-04-06T11:06:49+00:00","mainEntityOfPage":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/"},"wordCount":674,"publisher":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/#organization"},"image":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage"},"thumbnailUrl":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg","keywords":["caldeira","vapor"],"articleSection":["Ind\u00fastria"],"inLanguage":"pt-BR"},{"@type":"WebPage","@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/","url":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/","name":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira - Togawa Engenharia","isPartOf":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage"},"image":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage"},"thumbnailUrl":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1-300x207.jpg","datePublished":"2017-09-04T14:49:07+00:00","dateModified":"2026-04-06T11:06:49+00:00","breadcrumb":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#primaryimage","url":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg","contentUrl":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2017\/09\/9.1.jpg","width":892,"height":616},{"@type":"BreadcrumbList","@id":"https:\/\/togawaengenharia.com.br\/blog\/alimentacao-de-agua-da-caldeira\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/togawaengenharia.com.br\/blog\/"},{"@type":"ListItem","position":2,"name":"Alimenta\u00e7\u00e3o de \u00c1gua da Caldeira"}]},{"@type":"WebSite","@id":"https:\/\/togawaengenharia.com.br\/blog\/#website","url":"https:\/\/togawaengenharia.com.br\/blog\/","name":"Togawa Engenharia","description":"Blog Industrial","publisher":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/togawaengenharia.com.br\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Organization","@id":"https:\/\/togawaengenharia.com.br\/blog\/#organization","name":"Togawa Engenharia","url":"https:\/\/togawaengenharia.com.br\/blog\/","logo":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2016\/08\/Logo-togawa1.png","contentUrl":"https:\/\/togawaengenharia.com.br\/blog\/wp-content\/uploads\/2016\/08\/Logo-togawa1.png","width":227,"height":71,"caption":"Togawa Engenharia"},"image":{"@id":"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/togawaengenharia.com.br\/blog\/#\/schema\/person\/2b97ffcae08c230f737a2572c9cb161d","name":"Victor Togawa","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/eb1c652a344ecc9433e2dc053fe9c933f0bd9474cc37afcad12090a4b72b5719?s=96&d=mm&r=g","caption":"Victor Togawa"}}]}},"_links":{"self":[{"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/posts\/300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/comments?post=300"}],"version-history":[{"count":4,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/posts\/300\/revisions"}],"predecessor-version":[{"id":809,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/posts\/300\/revisions\/809"}],"wp:attachment":[{"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/media?parent=300"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/categories?post=300"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/togawaengenharia.com.br\/blog\/wp-json\/wp\/v2\/tags?post=300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}